Abstract

Loop heat pipe is a passive two-phase heat transfer device. The key component of loop heat pipe is the evaporator. In this study, the gas-liquid two-phase behavior inside two-dimensional porous medium with a single-pore size and multi-pore size distributions was comparatively studied, both experimentally and numerically by Lattice Boltzmann Method. With a constant heat flux applied to the evaporator's shell, the wick initially fills with saturated liquid, then undergoes evaporation with vapor invasion, and partially dries out with a gas-liquid interface. Due to the multi-pore size distribution in porous medium, vapor is more easily expelled from the wick. There is a significant difference gas-liquid interface inside the wick between the single-pore size wick and the multi-pore size wick, and the temperature of the evaporator's shell of the multi-pore size wick is 27.6% lower than that of the single-pore size wick. To validate the numerical results, two loop heat pipes were built, including monoporous wick and biporous wick, respectively. The experiment found that under high power, the performance of loop heat pipe with biporous wick is significantly better than that of loop heat pipe with monoporous wick. The temperature of the biporous wick is 9.79K lower than that of the monoporous wick at 230W. Experiments and simulations show that the porous medium with multi-pore have better performance.

This content is only available via PDF.
You do not currently have access to this content.