Magnetic Flux Leakage (MFL) is currently the standard method of gas pipeline inspection in spite of the fact that the accuracy of MFL is only about 10%. Ultrasonic inspection has much better accuracy and is not sensitive to permeability changes but normally requires a liquid couplant to get sufficient energy into the pipe wall. Reported here are the laboratory results of Gas Technology Institute’s (GTI) effort to investigate newly developed transducers that use gas as the coupling media. The combination of transducers specifically designed for this application and high gain amplifiers produced signals strong enough to measure wall thickness in steel at pressures from 200 to 1000 PSIG. Investigations showed that both the sensitivity of the transducers and the gas-metal coupling are functions of pressure and, therefore, limit the useful pressure range. Tests were run in pulse-echo mode and pitch-catch mode to determine the advantages and limitations of each. The average ultrasonic wall thickness will be used to calibrate the MFL improving the accuracy of its measurements.

1.
Drury
,
J. C.
, and
Marino
,
A.
,“
A Comparison of the Magnetic Flux Leakage and Ultrasonic Methods in the Detection and Measurement of Corrosion Pitting in Ferrous Plate and Pipe
,”
15th World Conference on Non-Destructive Testing
, Rome, October 2000.
2.
Westwood
,
Stephen
, and
Cholowsky
,
Sharon
, “
Independent Experimental Verification of the Sizing Accuracy of Magnetic Flux Leakage Tools
,”
7th International Pipeline Conference
, Mexico, November 2000.
3.
Bhardwaj
,
M. C.
, 2002, “
Non-Destructive Evaluation: Introduction of Non-Contact Ultrasound
,”
Encyclopedia of Smart Materials
, edited by
M.
Schwartz
,
Wiley
, New York, pp.
690
714
.
4.
Bhardwaj
,
M. C.
, “
High Efficiency Non-Contact Transducers and a Very High Coupling Piezoelectric Composite
,”
Proceedings World Conference on Non Destructive Testing
, August-September 2004, Montreal, Canada.
5.
Gan
,
T. H.
,
Hutchins
,
D. A.
, and
Billson
,
D. R.
, 2002, “
Air-Coupled Ultrasonic Inspection of Food Containers
,”
J. Food. Eng.
0260-8774,
53
, pp.
315
323
.
6.
McIntyre
,
C. S.
,
Hutchins
,
D. A.
,
Billson
,
D. R.
, and
Storr-Pelinen
,
J.
, 2001, “
The Use of Air-Coupled Ultrasound to Test Paper
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
0885-3010
48
, pp.
717
727
.
7.
Fortunko
,
C. M.
,
Renken
,
M. C.
, and
Murray
,
A.
, 1990, “
Examination of Objects Made of Wood Using Air Coupled Ultrasound
,”
Proc.-IEEE Ultrason. Symp.
1051-0117,
2
, pp.
1099
1103
.
8.
Kelly
,
S. P.
,
Farlow
,
R.
, and
Hayward
,
G.
, 1996, “
Application of Through-Air Ultrasound for Rapid NDE Scanning in the Aerospace Industry
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
0885-3010,
43
, pp.
581
591
.
9.
Safaeinili
,
A.
,
Lobkis
,
O. I.
, and
Chimenti
,
D. E.
, 1996, “
Air-Coupled Ultrasonic Estimation of Viscoelastic Stiffness in Plates
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
0885-3010,
43
, pp.
1171
1180
.
10.
Fortunko
,
C. M.
,
Dube
,
W. P.
, and
McColskey
,
J. D.
, 1993, “
Gas-Coupled Acoustic Microscopy in the Pulse-Echo Mode
,”
Proc.-IEEE Ultrason. Symp.
1051-0117,
2
, pp.
667
671
.
11.
Schramm
,
R. E.
, and
Fortunko
,
C. M.
, 2000, “
High Pressure Gas Coupled Ultrasonic Inspection for Discontinuities
,”
Mater. Eval.
0025-5327,
58
, pp.
558
563
.
12.
Teitsma
, an
Albert
, 2003, “
Gas-Coupled Ultrasonic Inspection of Pipelines
,”
Pipeline Gas J.
0032-0188,
230
(
8
), pp.
38
41
.
You do not currently have access to this content.