An overlying problem with shunting cerebrospinal fluid (CSF) is that there is no way to directly measure the volume being drained through a shunt once it has been implanted. Therefore, it becomes very difficult to determine if the shunt is working properly. If the patient’s symptoms remain unchanged, the shunt may not be draining fluid, the pressure setting on the shunt may need to be changed, or the patient may simply be unresponsive to shunt treatment. The objective is to develop a prototype shunt device which is capable of measuring, recording, and controlling the amount of CSF that passes through it on a daily basis. By using a positive displacement pump and controlling the stroke frequency, a volume of fluid similar to CSF (water) is controlled, measured, and recorded. If the volume of CSF being drained could be measured and controlled, this would make troubleshooting much easier. By using a bicorporeal device, power supply, and pumping device, it is hypothesized that shunting can be achieved with success.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Evaluation of a Novel Method of Shunting for Patients With Normal Pressure Hydrocephalus
Julian Lin
Julian Lin
Saint Francis Hospital
Search for other works by this author on:
Kalyani Nair
Bradley University
Martin Morris
Bradley University
Charles Corrie
Bradley University
Brian Del-Bene
Bradley University
Michelle Eastburn
Bradley University
Julian Lin
Saint Francis Hospital
J. Med. Devices. Jun 2011, 5(2): 027512 (1 pages)
Published Online: June 9, 2011
Article history
Online:
June 9, 2011
Published:
June 9, 2011
Citation
Nair, K., Morris, M., Corrie, C., Del-Bene, B., Eastburn, M., and Lin, J. (June 9, 2011). "Evaluation of a Novel Method of Shunting for Patients With Normal Pressure Hydrocephalus." ASME. J. Med. Devices. June 2011; 5(2): 027512. https://doi.org/10.1115/1.3589829
Download citation file:
1,051
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
A Hydraulically Controlled Nonoperative Magnetic Treatment for Long Gap Esophageal Atresia
J. Med. Devices (June,2011)
An Advanced Patient Lift and Transfer Device for the Home
J. Med. Devices (March,2010)
Innovative Renal Cooling Device for Use in Minimally Invasive Surgery
J. Med. Devices (June,2011)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Potential Application II-Brain Stroke Detection
Basic Principles and Potential Applications of Holographic Microwave Imaging
Human Brain with α Wave and Learning Memory Analysis under External Environment Variations
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)
History-Based Dynamic Quorum for Handling Split-Brain Syndrome in Distributed Computing
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)