Elasticity is an important physical attribute of biological tissue. Elasticity of normal tissue can differ significantly with pathological tissue in its stiffness. It is important to develop a clinical viable method to determine and visualize the elasticity of histological tissue. Magnetic resonance (MR) elastography is a promising noninvasive method to quantitatively measure the viscoelastic properties of biological tissue. We developed a new quasi-static actuation system with the spatial modulation of magnetization (SPAMM) imaging pulse sequence. The MR compatible actuation system consists of an ultrasonic motor, a force sensor, motion-transmission mechanism, ECG signal generation, and controller. The high torque ultrasonic motor, USR60-E3 by Shinsei Corporation, Japan, can function well in the magnetic environment. The simulated ECG signal is generated using function generator, and outputted to both MR scanner and controller respectively. SPAMM imaging sequence is utilized to acquire tagging images of the deformed tissue. The actuation is synchronized with the SPAMM sequence via simulated ECG signal. Indentation force is measured by MR compatible force sensor for the subsequent stiffness inversion procedure. Imaging experiments were conducted using this actuation system and a GE SIGNA 1.5T MR scanner. Clear tag-deformed images of agar gel phantom have been acquired. The results demonstrated the feasibility of utilizing SPAMM sequence and the proposed actuation system for tissue characterization. In comparison with dynamic method of MR elastography, this quasi-static method is relatively simple to implement since no motion sensitive gradient or gradient synchronization is required. A limitation of indentation method is the difficulty to obtain significant deformation of tumor inside the liver organ. Since radio frequency (RF) needle is inserted into liver organ during tumor ablation, the proposed system with needle-based actuation making use of this inevitable insertion will be able to intra-operatively image the liver tumor during ablation. The RF needle can directly vibrate the pathological tissue within the liver organ.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
A New Actuation System With Simulated Electrocardiogram Signal for MR Elastography
Cheekong Chui
Cheekong Chui
National University of Singapore
Search for other works by this author on:
Cheekong Chui
National University of Singapore
J. Med. Devices. Jun 2010, 4(2): 027520 (1 pages)
Published Online: August 10, 2010
Article history
Published:
August 10, 2010
Citation
Chui, C. (August 10, 2010). "A New Actuation System With Simulated Electrocardiogram Signal for MR Elastography." ASME. J. Med. Devices. June 2010; 4(2): 027520. https://doi.org/10.1115/1.3443173
Download citation file:
680
Views
Get Email Alerts
Cited By
Validation of a Repurposed pH Monitoring Capsule for Cecal Applications Using Novel Synthetic Cecal Contents
J. Med. Devices (March 2025)
Related Articles
Liver Tolerance to Repeat 90Y-Microsphere Radioembolization
J. Med. Devices (June,2008)
Hertz Contact Based Scaling of Puncture Forces for Large Scale Needle Prototypes Using a Gelatinous Tissue Phantom
J. Med. Devices (June,2010)
Reduction of Noise From MR Thermometry Measurements During HIFU Characterization Procedures
J. Nanotechnol. Eng. Med (May,2011)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Using Statistical Learning Theory to Improve Treatment Response for Metastatic Colorectal Carcinoma
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20
Characterization of Skeletal Muscle Elasticity Using Magnetic Resonance Elastography
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)