The transient calorimetric technique was used to measure the total hemispherical emissivity of conductive materials. The emissivity was measured in a small central region of a thin strip heated electrically in a vacuum chamber. The axial heat transfer along the sample and the heat losses from the wires were considered in the transient heat transfer calculations. An appropriate time interval for the hot sample cooling rate is needed to improve the emissivity solution accuracy. Two ways were used to analyze the data, based on the known specific heat and the assumed functions of the emissivity and the specific heat. Comparisons with steady-state data showed that their results are very similar with a maximum difference of only 13% (944 K). Therefore, the transient method based on the function assumption is a good choice for measurements when there are inaccurate or insufficient specific heat data at the desired temperatures. Since ferromagnetic materials have Curie points at higher temperatures, this study also investigated the applicability of the transient calorimetric technique for high temperature emissivity measurements. For higher temperatures above the Curie point, the steady-state method is more accurate than the transient method. These analyses provide a comprehensive understanding of the transient method for measuring the total hemispherical emissivity.
Skip Nav Destination
Article navigation
November 2012
This article was originally published in
Journal of Heat Transfer
Research-Article
Transient Calorimetric Measurement Method for Total Hemispherical Emissivity
Tairan Fu,
Tairan Fu
1
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education,
Department of Thermal Engineering,
e-mail: trfu@mail.tsinghua.edu.cn
Department of Thermal Engineering,
Tsinghua University
,Beijing 100084
, P. R. China
;Beijing Key Laboratory of CO2 Utilization and Reduction Technology
,Beijing 100084
, P. R. China
e-mail: trfu@mail.tsinghua.edu.cn
1Corresponding author.
Search for other works by this author on:
Peng Tan
Peng Tan
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education,
Department of Thermal Engineering,
Department of Thermal Engineering,
Tsinghua University
,Beijing 100084
, P. R. China
Search for other works by this author on:
Tairan Fu
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education,
Department of Thermal Engineering,
e-mail: trfu@mail.tsinghua.edu.cn
Department of Thermal Engineering,
Tsinghua University
,Beijing 100084
, P. R. China
;Beijing Key Laboratory of CO2 Utilization and Reduction Technology
,Beijing 100084
, P. R. China
e-mail: trfu@mail.tsinghua.edu.cn
Peng Tan
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education,
Department of Thermal Engineering,
Department of Thermal Engineering,
Tsinghua University
,Beijing 100084
, P. R. China
1Corresponding author.
Contributed by the Heat Transfer Division of ASME for publication in the JOURNALOF HEAT TRANSFER. Manuscript received May 25, 2011; final manuscript received May 15, 2012; published online September 24, 2012. Assoc. Editor: He-Ping Tan.
J. Heat Transfer. Nov 2012, 134(11): 111601 (7 pages)
Published Online: September 24, 2012
Article history
Received:
May 25, 2011
Revision Received:
May 15, 2012
Citation
Fu, T., and Tan, P. (September 24, 2012). "Transient Calorimetric Measurement Method for Total Hemispherical Emissivity." ASME. J. Heat Transfer. November 2012; 134(11): 111601. https://doi.org/10.1115/1.4006896
Download citation file:
Get Email Alerts
Cited By
On Prof. Roop Mahajan's 80th Birthday
J. Heat Mass Transfer
Thermal Hydraulic Performance and Characteristics of a Microchannel Heat Exchanger: Experimental and Numerical Investigations
J. Heat Mass Transfer (February 2025)
Related Articles
Simultaneous Retrieval of Total Hemispherical Emissivity and Specific Heat From Transient Multimode Heat Transfer Experiments
J. Heat Transfer (June,2008)
Measurement of Total Hemispherical Emittance and Specific Heat of Aluminum and Inconel 718 by a Calorimetric Technique
J. Heat Transfer (March,2006)
Experiments in Single-Phase Natural Circulation Miniloops With Different Working Fluids and Geometries
J. Heat Transfer (October,2008)
Some Effects of Start-Up and Shut-Down on Thrust Bearing Assemblies in Hydro-Generators
J. Tribol (October,2003)
Related Proceedings Papers
Related Chapters
Simultaneous Thermal Conductivity and Specific Heat Measurements of Thin Samples by Transient Joule Self-Heating
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential