A criterion for comparing the relative performance of various heat transfer augmentation methods used in constant power input systems is introduced. The analysis is based on the principle of minimizing the rate of total entropy generation. The heat transfer load (HTL), a parameter determined by the operating requirements of the heat dissipating process that indicates the difficulty of the heat transfer duty to be performed, is defined in the present study. By comparing the irreversibility distribution ratio (φ) of various configurations at a given heat transfer load, the most exergy efficient system can be selected. The data for three different types of fin configurations used in two constant power input applications (electronic equipment and internal turbine blade cooling) are utilized in demonstrating the technique. The results indicate which specific fin geometry of the particular configuration type analyzed will transfer the dissipated heat at the specified base surface temperature while requiring the least pumping power. Although the φ versus HTL criterion is applied to only fins in this study, the method can be extended to many other applications such as jet impingement cooling or mass transfer.
Skip Nav Destination
Article navigation
Research Papers
Second Law Analysis in Assessing Constant Power Input Systems
R. K. Wilcoxon,
R. K. Wilcoxon
Mechanical Engineering Department, South Dakota State University, Brookings, SD 57007
Search for other works by this author on:
A. Moutsoglou
A. Moutsoglou
Mechanical Engineering Department, South Dakota State University, Brookings, SD 57007
Search for other works by this author on:
R. K. Wilcoxon
Mechanical Engineering Department, South Dakota State University, Brookings, SD 57007
A. Moutsoglou
Mechanical Engineering Department, South Dakota State University, Brookings, SD 57007
J. Heat Transfer. May 1991, 113(2): 321-328 (8 pages)
Published Online: May 1, 1991
Article history
Received:
June 11, 1990
Revised:
October 5, 1990
Online:
May 23, 2008
Citation
Wilcoxon, R. K., and Moutsoglou, A. (May 1, 1991). "Second Law Analysis in Assessing Constant Power Input Systems." ASME. J. Heat Transfer. May 1991; 113(2): 321–328. https://doi.org/10.1115/1.2910564
Download citation file:
Get Email Alerts
Cited By
Related Articles
Constructal Trees of Convective Fins
J. Heat Transfer (August,1999)
A Brief on Biological Thermodynamics for Human Physiology
J Biomech Eng (July,2021)
Optimal Spacing Between Pin Fins With Impinging Flow
J. Heat Transfer (August,1996)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Liquid Cooled Systems
Thermal Management of Telecommunications Equipment
Thermal Design Guide of Liquid Cooled Systems
Thermal Design of Liquid Cooled Microelectronic Equipment