A combined cycle power plant (or any power plant, for that matter) does very rarely—if ever—run at the exact design point ambient and loading conditions. Depending on the demand for electricity, market conditions, and other considerations of interest to the owner of the plant and the existing ambient conditions, a combined cycle plant will run under boundary conditions that are significantly different from those for which individual components are designed. Accurate calculation of the “off-design” performance of the overall combined cycle system and its key subsystems requires highly detailed and complicated computer models. Such models are crucial to high-fidelity simulation of myriad off-design performance scenarios for control system development to ensure safe and reliable operability in the field. A viable option in lieu of sophisticated system simulation is making use of the normalized curves that are generated from rigorous model runs and applying the factors read from such curves to a known design performance to calculate the off-design performance. This is the common method adopted in the fulfillment of commercial transactions. These curves; however, are highly system-specific and their broad applicability to a wide variety of configurations is limited. Utilizing the key principles of the second law of thermodynamics, this paper describes a simple, physics-based calculation method to estimate the off-design performance of a combined cycle power plant. The method is shown to be quite robust within a wide range of operating regimes for a generic combined cycle system. As such, a second-law-based approach to off-design performance estimation is a highly viable tool for plant engineers and operators in cases where calculation speed with a small sacrifice in fidelity is of prime importance.
Skip Nav Destination
Article navigation
January 2012
Research Papers
Combined Cycle Off-Design Performance Estimation: A Second-Law Perspective
J Joseph
J Joseph
Lead Engineer
Search for other works by this author on:
S. Can Gülen
Principal Engineer
J Joseph
Lead Engineer
J. Eng. Gas Turbines Power. Jan 2012, 134(1): 011801 (11 pages)
Published Online: November 7, 2011
Article history
Received:
April 25, 2011
Accepted:
April 27, 2011
Online:
November 7, 2011
Published:
November 7, 2011
Citation
Can Gülen, S., and Joseph, J. (November 7, 2011). "Combined Cycle Off-Design Performance Estimation: A Second-Law Perspective." ASME. J. Eng. Gas Turbines Power. January 2012; 134(1): 011801. https://doi.org/10.1115/1.4004179
Download citation file:
Get Email Alerts
Cited By
Shape Optimization of an Industrial Aeroengine Combustor to reduce Thermoacoustic Instability
J. Eng. Gas Turbines Power
Dynamic Response of A Pivot-Mounted Squeeze Film Damper: Measurements and Predictions
J. Eng. Gas Turbines Power
Review of The Impact Of Hydrogen-Containing Fuels On Gas Turbine Hot-Section Materials
J. Eng. Gas Turbines Power
Effects of Lattice Orientation Angle On Tpms-Based Transpiration Cooling
J. Eng. Gas Turbines Power
Related Articles
Second Law Efficiency of the Rankine Bottoming Cycle of a Combined Cycle Power Plant
J. Eng. Gas Turbines Power (January,2010)
A Computational Model of a Combined Cycle Power Generation Unit
J. Energy Resour. Technol (September,2004)
Importance of Auxiliary Power Consumption for Combined Cycle Performance
J. Eng. Gas Turbines Power (April,2011)
Achieving Better Power Plant Guarantees Through a New Exergy-Based Approach for the HRSG
J. Eng. Gas Turbines Power (January,2022)
Related Proceedings Papers
Related Chapters
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration