Throughout the history of turbomachines investigators have tried to develop reliable methods for prediction of centrifugal pump behavior. Among the parameters available to estimate the performance of this kind of machine is the slip factor. In spite of being regarded as a variable of great significance in the analysis of turbomachinery, there seem to be a misconception regarding its concept and application. Indeed, empirical correlations have been widely used to estimate the slip factor, even in the case of two-phase flow applications, where it has not been investigated. Moreover, these correlations provide a constant value of the slip factor for a given impeller only at the best efficiency point, which is an important restriction to the pump performance prediction, considering that slip factor varies with the pump flow rate. In this study, three-dimensional computational fluid dynamics simulations were carried out on an impeller of known geometry from which values of slip factor were calculated for both single- and two-phase flow (water and water-air). These results include curves of the slip factor as a function of the specific capacity and the gas-void fraction. Additionally, results for the slip factor in the case of single-phase flow (water) are given for various centrifugal impellers (, 1447, 1612, and 3513) in order to illustrate the influence of the flow rate on this parameter. Finally, based on the numerical results, a methodology for prediction of the pump head is presented. Excellent agreement with experimental results has been found. This paper attempts to contribute to a better understanding of the fluid dynamics within centrifugal pump impellers and to shed more light on the path that prediction models should follow in the future.
Skip Nav Destination
Article navigation
March 2005
Technical Papers
Slip Factor for Centrifugal Impellers Under Single and Two-Phase Flow Conditions
José A. Caridad,
José A. Caridad
Laboratorio de Conversión de Energía Mecánica,
Universidad Simón Bolívar
, Caracas, Venezuela
Search for other works by this author on:
Frank Kenyery
Frank Kenyery
Laboratorio de Conversión de Energía Mecánica,
Universidad Simón Bolívar
, Caracas, Venezuela
Search for other works by this author on:
José A. Caridad
Laboratorio de Conversión de Energía Mecánica,
Universidad Simón Bolívar
, Caracas, Venezuela
Frank Kenyery
Laboratorio de Conversión de Energía Mecánica,
Universidad Simón Bolívar
, Caracas, VenezuelaJ. Fluids Eng. Mar 2005, 127(2): 317-321 (5 pages)
Published Online: October 12, 2004
Article history
Received:
February 18, 2004
Revised:
October 12, 2004
Citation
Caridad, J. A., and Kenyery, F. (October 12, 2004). "Slip Factor for Centrifugal Impellers Under Single and Two-Phase Flow Conditions." ASME. J. Fluids Eng. March 2005; 127(2): 317–321. https://doi.org/10.1115/1.1891153
Download citation file:
Get Email Alerts
Related Articles
CFD Analysis of Electric Submersible Pumps (ESP) Handling Two-Phase Mixtures
J. Energy Resour. Technol (June,2004)
Hydrodynamic Design of Rotodynamic Pump Impeller for Multiphase Pumping by Combined Approach of Inverse Design and CFD Analysis
J. Fluids Eng (March,2005)
Transient Behavior of Turbomachineries: Applications to Radial Flow Pump Startups
J. Fluids Eng (November,2007)
Unsteady Flow Patterns for a Double Suction Centrifugal Pump
J. Fluids Eng (July,2009)
Related Proceedings Papers
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Introduction
Mixed-flow Pumps: Modeling, Simulation, and Measurements