The capacity reduction of a solid-polymer-membrane-type fuel cell (PEFC) with a reformer by load leveling and by improving the efficiency of part-load operation of the reformer is considered. The power generation efficiency of a fuel cell improves by supplying gas with a high oxygen concentration to the cathode. During periods of low electricity demand, the fuel cell is operated using reformed gas and air, and water electrolysis operation is also performed. When the electric power load is large, gases stored in cylinders are supplied to the fuel cell for operation. Using the proposed method, high efficiency operation and a reduction in the fuel cell capacity are possible.
Issue Section:
Technical Papers
1.
Oda
, K.
, Sakamoto
, S.
, Ueda
, M.
, Fuji
, A.
, and Ouki
, T.
, 1999, “A Small-Scale Reformer for Fuel Cell Application
,” Sanyo Technical Review
, 31
(2
), pp. 99
–106
(in Japanese).2.
Takeda
, Y.
, Iwasaki
, Y.
, Imada
, N.
, and Miyata
, T.
, 2004, “Development of Fuel Processor for Rapid Start-up
,” Proc. 20th Energy System Economic and Environment Conference
, K.
Kimura
, ed., pp. 343
–344
(in Japanese).3.
Ibe
, S.
, Shinke
, N.
, Takami
, S.
, Yasuda
, Y.
, Asatsu
, H.
, and Echigo
, M.
, 2002, “Development of Fuel Processor for Residential Fuel Cell Cogeneration System
,” Proc. 21st Annual Meeting of Japan Society of Energy and Resources
, K.
Abe
, ed., Osaka, June 12-13, pp. 493
–496
(in Japanese).4.
Zhang
, Y.
, Ouyang
, M.
, Lu
, Q.
, Luo
, J.
, and Li
, X.
, 2004, “A Model Predicting Performance of Proton Exchange Membrane Fuel Cell Stack Thermal Systems
,” Appl. Therm. Eng.
1359-4311, 24
, pp. 501
–513
.5.
Sedghisigarchi
, K.
, 2004, “Dynamic and Transient Analysis of Power Distribution System with Fuel Cells-Part 1: Fuel-Cell Dynamic Model
,” IEEE Trans. Energy Convers.
0885-8969, 19
(2
), pp. 423
–428
.6.
Hamelin
, J.
, Agbossou
, K.
, Laperriere
, A.
, Laurencelle
, F.
, and Bose
, T. K.
, 2001, “Dynamic Behavior of a PEM Fuel Cell Stack for Stationary Applications
,” Int. J. Hydrogen Energy
0360-3199, 26
, pp. 625
–629
.7.
Yerramalla
, S.
, Davari
, A.
, Feliachi
, A.
, and Biswas
, T.
, 2003, “Modeling and Simulation of the Dynamic Behavior of a Polymer Electrolyte Membrane Fuel Cell
,” J. Power Sources
0378-7753, 124
, pp. 104
–113
.8.
Mikkola
, M.
, 2001, “Experimental Studies on Polymer Electrolyte Membrane Fuel Cell Stacks
,” Master’s Science thesis Helsinki University of Technology, Helsinki, Finland, pp. 58
–79
.9.
Ibaraki Prefecture Government Office of Education
, 2002, “Modeling of Hydrogen Energy System
,” Ibaraki, Japan, High School Active Science Project Research Report (in Japanese).10.
Badami
, M.
, and Caldera
, C.
, 2002, “Dynamic Model of a Load-Following Fuel Cell Vehicle: Impact of the Air System
,” SAE Tech. Pap.
0148-7191, PT–96, 2002–01–0100, pp. 1
–10
.11.
Morner
, S. O.
, and Klein
, S. A.
, 2001, “Experimental Evaluation of the Dynamic Behavior of an Air-Breathing Fuel Cell Stack
,” ASME J. Sol. Energy Eng.
0199-6231, August, 123
(3
), pp. 225
–231
.12.
Colling
, A. K.
, and Roy
, R. J.
, 1998, “Development Status and Testing of High Differential Pressure SPE Water Electrolysis Cells
,” SAE Tech. Pap. Ser.
0148-7191, pp. 1
–8
.13.
Nagai
, M.
, Tazima
, H.
, Sakanishi
, A.
, Hisatome
, N.
, and Ohkura
, S.
, 1996, “Development on Solid Polymer Electrolyte Water Electrolysis Technology for High Current Density and Energy Efficiency
,” Proceedings 11th Hydrogen Energy Prog.
, 1
, Frankfurt, pp. 825
–830
.14.
National Astronomical Observatory
, 2003, “Rika Nenpyo
,” Chronological Scientific Tables (CD-ROM), Maruzen Co., Ltd., Tokyo.Copyright © 2007
by American Society of Mechanical Engineers
You do not currently have access to this content.