Bileaflet mechanical heart valves (BMHVs) are among the most popular prostheses to replace defective native valves. However, complex flow phenomena caused by the prosthesis are thought to induce serious thromboembolic complications. This study aims at employing a novel multiscale numerical method that models realistic sized suspended platelets for assessing blood damage potential in flow through BMHVs. A previously validated lattice-Boltzmann method (LBM) is used to simulate pulsatile flow through a 23 mm St. Jude Medical (SJM) Regent™ valve in the aortic position at very high spatiotemporal resolution with the presence of thousands of suspended platelets. Platelet damage is modeled for both the systolic and diastolic phases of the cardiac cycle. No platelets exceed activation thresholds for any of the simulations. Platelet damage is determined to be particularly high for suspended elements trapped in recirculation zones, which suggests a shift of focus in blood damage studies away from instantaneous flow fields and toward high flow mixing regions. In the diastolic phase, leakage flow through the b-datum gap is shown to cause highest damage to platelets. This multiscale numerical method may be used as a generic solver for evaluating blood damage in other cardiovascular flows and devices.
Skip Nav Destination
e-mail: min@gatech.edu
e-mail: cyrus.aidun@me.gatech.edu
Article navigation
October 2014
Research-Article
Blood Damage Through a Bileaflet Mechanical Heart Valve: A Quantitative Computational Study Using a Multiscale Suspension Flow Solver
B. Min Yun,
e-mail: min@gatech.edu
B. Min Yun
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
e-mail: min@gatech.edu
Search for other works by this author on:
Cyrus K. Aidun,
e-mail: cyrus.aidun@me.gatech.edu
Cyrus K. Aidun
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
Parker H. Petit Institute for
Bioengineering and Bioscience
,315 Ferst Dr. NW
,Atlanta, GA 30332
e-mail: cyrus.aidun@me.gatech.edu
Search for other works by this author on:
Ajit P. Yoganathan
Ajit P. Yoganathan
1
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
Parker H. Petit Institute for
Bioengineering and Bioscience
,315 Ferst Dr. NW
,Atlanta, GA 30332
Wallace H. Coulter Department of
Biomedical Engineering,
e-mail: ajit.yoganathan@bme.gatech.edu
Biomedical Engineering,
School of Chemical and
Biomolecular Engineering
,313 Ferst Drive
,Atlanta, GA 30332-0535
e-mail: ajit.yoganathan@bme.gatech.edu
1Corresponding author.
Search for other works by this author on:
B. Min Yun
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
e-mail: min@gatech.edu
Cyrus K. Aidun
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
Parker H. Petit Institute for
Bioengineering and Bioscience
,315 Ferst Dr. NW
,Atlanta, GA 30332
e-mail: cyrus.aidun@me.gatech.edu
Ajit P. Yoganathan
G.W. Woodruff School of Mechanical Engineering
,801 Ferst Drive
,Atlanta, GA 30332-0405
Parker H. Petit Institute for
Bioengineering and Bioscience
,315 Ferst Dr. NW
,Atlanta, GA 30332
Wallace H. Coulter Department of
Biomedical Engineering,
e-mail: ajit.yoganathan@bme.gatech.edu
Biomedical Engineering,
School of Chemical and
Biomolecular Engineering
,313 Ferst Drive
,Atlanta, GA 30332-0535
e-mail: ajit.yoganathan@bme.gatech.edu
1Corresponding author.
Manuscript received December 9, 2013; final manuscript received July 18, 2014; accepted manuscript posted July 30, 2014; published online August 12, 2014. Assoc. Editor: Alison Marsden.
J Biomech Eng. Oct 2014, 136(10): 101009 (17 pages)
Published Online: August 12, 2014
Article history
Received:
December 9, 2013
Revision Received:
July 18, 2014
Accepted:
July 30, 2014
Citation
Min Yun, B., Aidun, C. K., and Yoganathan, A. P. (August 12, 2014). "Blood Damage Through a Bileaflet Mechanical Heart Valve: A Quantitative Computational Study Using a Multiscale Suspension Flow Solver." ASME. J Biomech Eng. October 2014; 136(10): 101009. https://doi.org/10.1115/1.4028105
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
Numerical Simulation of Wall Shear Stress Conditions and Platelet Localization in Realistic End-to-Side Arterial Anastomoses
J Biomech Eng (October,2003)
Design of a Pulsatile Flow Facility to Evaluate Thrombogenic Potential of Implantable Cardiac Devices
J Biomech Eng (April,2015)
Two-Component Laser Velocimeter Measurements Downstream of Heart Valve Prostheses in Pulsatile Flow
J Biomech Eng (February,1986)
Vortex Shedding as a Mechanism for Free Emboli Formation in Mechanical Heart Valves
J Biomech Eng (April,2000)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices