Computational studies of deep pressure sores (DPS) in skeletal muscles require information on viscoelastic constitutive behavior of muscles, particularly when muscles are loaded transversally as during bone-muscle interaction in sitting and lying immobilized patients. In this study, we measured transient shear moduli of fresh porcine muscles in vitro using the indentation method. We employed a custom-made pneumatic device that allowed rapid indentations. We tested 8 gluteus muscles, harvested from 5 adult pigs. Each muscle was indented transversally (perpendicularly to the direction of fibers) at 3 different sites, 7 times per site, to obtain nonpreconditioned (NPC) and preconditioned (PC) data. Short-term and long-term shear moduli were obtained directly from experiments. We further fitted measured data to a biexponential equation , which provided good fit, visually and in terms of the correlation coefficients. Typically, plateau of the stress relaxation curves (defined as 10% difference from final ) was evident after indentation. Short-term shear moduli (mean NPC: , PC: ) were greater than long-term moduli (NPC: , PC: ) by about an order of magnitude. Statistical analysis of parameters showed that only was affected by preconditioning, while , , , , , and properties were unaffected. Since DPS develop over time scales of minutes to hours, but most stress relaxation occurs within , the most relevant property for computational modeling is (mean ), which is, conveniently, unaffected by preconditioning.
Skip Nav Destination
e-mail: gefen@eng.tau.ac.il
Article navigation
October 2006
Technical Briefs
Stress Relaxation of Porcine Gluteus Muscle Subjected to Sudden Transverse Deformation as Related to Pressure Sore Modeling
Avital Palevski,
Avital Palevski
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Search for other works by this author on:
Ittai Glaich,
Ittai Glaich
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Search for other works by this author on:
Sigal Portnoy,
Sigal Portnoy
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Search for other works by this author on:
Eran Linder-Ganz,
Eran Linder-Ganz
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Search for other works by this author on:
Amit Gefen
Amit Gefen
Department of Biomedical Engineering, Faculty of Engineering,
e-mail: gefen@eng.tau.ac.il
Tel Aviv University
, Tel Aviv 69978, Israel
Search for other works by this author on:
Avital Palevski
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Ittai Glaich
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Sigal Portnoy
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Eran Linder-Ganz
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israel
Amit Gefen
Department of Biomedical Engineering, Faculty of Engineering,
Tel Aviv University
, Tel Aviv 69978, Israele-mail: gefen@eng.tau.ac.il
J Biomech Eng. Oct 2006, 128(5): 782-787 (6 pages)
Published Online: April 9, 2006
Article history
Received:
July 29, 2005
Revised:
April 9, 2006
Citation
Palevski, A., Glaich, I., Portnoy, S., Linder-Ganz, E., and Gefen, A. (April 9, 2006). "Stress Relaxation of Porcine Gluteus Muscle Subjected to Sudden Transverse Deformation as Related to Pressure Sore Modeling." ASME. J Biomech Eng. October 2006; 128(5): 782–787. https://doi.org/10.1115/1.2264395
Download citation file:
Get Email Alerts
Related Articles
In Vivo Muscle Stiffening Under Bone Compression Promotes Deep Pressure Sores
J Biomech Eng (June,2005)
Dynamic, Regional Mechanical Properties of the Porcine Brain: Indentation in the Coronal Plane
J Biomech Eng (July,2011)
Development and Validation of a Three-Dimensional Finite Element Model of the Face
J Biomech Eng (April,2009)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Microstructure Evolution and Physics-Based Modeling
Ultrasonic Welding of Lithium-Ion Batteries
On the Evaluation of Thermal and Mechanical Factors in Low-Speed Sliding
Tribology of Mechanical Systems: A Guide to Present and Future Technologies