In subtalar arthrodesis operations, correction of the hindfoot alignment is performed in about half of the cases. To improve the quality of the operation, a measurement system was developed which reliably measures the hindfoot angle pre-, per-, and postoperatively. This device was evaluated by measuring subjects in standing weightbearing position and in prone nonweightbearing position. The results were compared with hindfoot angles constructed on posterior photographic images. The results are similar to other studies (all maximum values): intratester accuracy 1.4°, intertester accuracy 2.2°, intratester reliability 0.9, and intertester reliability 0.74. The proposed device will improve the quality of correction, because it enables peroperative measurement of hindfoot alignment.
Skip Nav Destination
e-mail: g.j.tuijthof@amc.uva.nl
e-mail: j.l.herder@wbmt.tudelft.nl
e-mail: pscholten@medinova.com
e-mail: c.n.vandijk@amc.uva.nl
e-mail: p.v.pistecky@wbmt.tudelft.nl
Article navigation
June 2004
Technical Papers
Measuring Alignment of the Hindfoot
Gabrielle J. M. Tuijthof,
e-mail: g.j.tuijthof@amc.uva.nl
Gabrielle J. M. Tuijthof
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
Department of Orthopaedics G4, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
Search for other works by this author on:
Just L. Herder,
e-mail: j.l.herder@wbmt.tudelft.nl
Just L. Herder
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
Search for other works by this author on:
Peter E. Scholten,
e-mail: pscholten@medinova.com
Peter E. Scholten
Department of Orthopaedic Surgery, Klein Rosendael Clinic, Rosendaalselaan 30, 6891 DG, Rozendaal, The Netherlands
Search for other works by this author on:
C. Niek van Dijk,
e-mail: c.n.vandijk@amc.uva.nl
C. Niek van Dijk
Department of Orthopaedics G4, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
Search for other works by this author on:
Peter V. Pistecky
e-mail: p.v.pistecky@wbmt.tudelft.nl
Peter V. Pistecky
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
Search for other works by this author on:
Gabrielle J. M. Tuijthof
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
Department of Orthopaedics G4, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
e-mail: g.j.tuijthof@amc.uva.nl
Just L. Herder
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
e-mail: j.l.herder@wbmt.tudelft.nl
Peter E. Scholten
Department of Orthopaedic Surgery, Klein Rosendael Clinic, Rosendaalselaan 30, 6891 DG, Rozendaal, The Netherlands
e-mail: pscholten@medinova.com
C. Niek van Dijk
Department of Orthopaedics G4, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
e-mail: c.n.vandijk@amc.uva.nl
Peter V. Pistecky
Man-Machine Systems and Control, Department of Design, Engineering, and Production, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands
e-mail: p.v.pistecky@wbmt.tudelft.nl
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division June 26, 2003; revision received October 27, 2003. Associate Editor: K. Vaughan.
J Biomech Eng. Jun 2004, 126(3): 357-362 (6 pages)
Published Online: June 24, 2004
Article history
Received:
June 26, 2003
Revised:
October 27, 2003
Online:
June 24, 2004
Citation
Tuijthof, G. J. M., Herder, J. L., Scholten, P. E., Niek van Dijk, C., and Pistecky, P. V. (June 24, 2004). "Measuring Alignment of the Hindfoot ." ASME. J Biomech Eng. June 2004; 126(3): 357–362. https://doi.org/10.1115/1.1762897
Download citation file:
Get Email Alerts
A New Dissipation Function to Model the Rate-Dependent Mechanical Behavior of Semilunar Valve Leaflets
J Biomech Eng (July 2023)
Muscle Constitutive Model With a Tangent Modulus Approximation: Ansys Implementation and Verification
J Biomech Eng (July 2023)
Related Articles
Design of a Compliant Steerable Arthroscopic Punch
J. Med. Devices (June,2010)
PMMA Implants Increase Femoral Strength
J. Med. Devices (June,2008)
A Measurement Device for Rotational Stiffness of the Eye
J. Med. Devices (June,2008)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
Related Chapters
Biomedical Imaging and Biosensing
Electromagnetic Induction Imaging: Theory and Biomedical Applications
Medical Imaging
Basic Principles and Potential Applications of Holographic Microwave Imaging
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging