The current trend in computational hemodynamics is to employ realistic models derived from ex vivo or in vivo imaging. Such studies typically produce a series of images from which the lumen boundaries must first be individually extracted (i.e., two-dimensional segmentation), and then serially reconstructed to produce the three-dimensional lumen surface geometry. In this paper, we present a rapid three-dimensional segmentation technique that combines these two steps, based on the idea of an expanding virtual balloon. This three-dimensional technique is demonstrated in application to finite element meshing and CFD modeling of flow in the carotid bifurcation of a normal volunteer imaged with black blood MRI. Wall shear stress patterns computed using a mesh generated with the three-dimensional technique agree well with those computed using a mesh generated from conventional two-dimensional segmentation and serial reconstruction. In addition to reducing the time required to extract the lumen surface from hours to minutes, our approach is easy to learn and use and requires minimal user intervention, which can potentially increase the accuracy and precision of quantitative and longitudinal studies of hemodynamics and vascular disease. [S0148-0731(00)00201-6]

1.
Giddens
,
D. P.
,
Zarins
,
C. K.
, and
Glagov
,
S.
,
1993
, “
The role of fluid mechanics in the localization and detection of atherosclerosis
,”
ASME J. Biomech. Eng.
,
115
, pp.
588
594
.
2.
Milner
,
J. S.
,
Moore
,
J. A.
,
Rutt
,
B. K.
, and
Steinman
,
D. A.
,
1998
, “
Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects
,”
J. Vasc. Surg.
,
28
, No.
1
, pp.
143
156
.
3.
Foutrakis
,
G. N.
,
Burgreen
,
G.
,
Yonas
,
H.
, and
Sclabassi
,
R. J.
,
1996
, “
Construction of 3-D arterial volume meshes from magnetic resonance angiography
,”
Neurobiological Res.
,
18
, pp.
354
360
.
4.
Gill
,
J. D.
,
Ladak
,
H. M.
,
Steinman
,
D. A.
, and
Fenster
,
A.
,
1999
, “
Development and evaluation of a semi-automatic 3D segmentation technique of the carotid arteries from 3D ultrasound images
,”
Proc. SPIE Image Processing
,
3661
, pp.
214
221
.
5.
Terzopoulos, D., and Vasilescu, M., 1991, “Sampling and reconstruction with adaptive meshes,” Proc. Conference on Computer Vision and Pattern Recognition, Maui, HI, pp. 70-75.
6.
Chen
,
Y.
, and
Medioni
,
G.
,
1995
, “
Description of complex objects from multiple range images using an inflating balloon model
,”
Comput. Vis. Image Underst.
,
61
, pp.
325
334
.
7.
Moore, J. A., 1998, “Computational blood flow modelling in realistic arterial geometries,” Ph.D. thesis, University of Toronto, Toronto, Canada.
8.
Ethier, C. R., Steinman, D. A., and Ojha, M., 1999, “Comparisons between computational hemodynamics, photochromic dye flow visualization and magnetic resonance velocimetry,” in: The Haemodynamics of Arterial Organs—Comparison of Computational Predictions With In Vivo and In Vitro Data, Xu, X. Y., and Collins, M. W., eds., WIT Press, Southampton.
9.
He
,
X.
, and
Ku
,
D. N.
,
1995
, “
Flow in T-bifurcations: Effect of the sharpness of the flow divider
,”
Biorheology
,
32
, No.
4
, pp.
447
458
.
10.
Friedman
,
M. H.
, and
Ehrlich
,
L. W.
,
1984
, “
Numerical simulation of aortic bifurcation flows: The effect of flow divider curvature
,”
J. Biomech.
,
17
, No.
12
, pp.
881
888
.
11.
Steinman
,
D. A.
, and
Rutt
,
B. K.
,
1998
, “
On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation
,”
Magn. Reson. Med.
,
39
, No.
4
, pp.
635
641
.
12.
McInerney
,
T.
, and
Terzopoulos
,
D.
,
1995
, “
A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis
,”
Comput. Med. Imaging Graph.
,
19
, No.
1
, pp.
69
83
.
You do not currently have access to this content.