The indentation problem of a thin layer of hydrated soft tissue such as cartilage or meniscus by a circular plane-ended indenter is investigated. The tissue is represented by a biphasic continuum model consisting of a solid phase (collagen and proteoglycan) and a fluid phase (interstitial water). A finite element formulation of the linear biphasic continuum equations is used to solve an axisymmetric approximation of the indentation problem. We consider stress-relaxation problems for which analytic solution is intractable; where the indenter is impermeable (solid) and/or when the interface between the indenter and tissue is perfectly adhesive. Thicknesses corresponding to a thin and thick specimen are considered to examine the effects of tissue thickness. The different flow, pressure, stress and strain fields which are predicted within the tissue, over time periods typically used in the mechanical testing of soft tissues, will be presented. Results are compared with the case of a porous free-draining indenter with a perfectly lubricated tissue-indenter interface, for which an analytic solution is available, to show the effects of friction at the tissue-indenter interface, and the effects of an impermeable indenter. While these effects are present for both thin and thick tissues, they are shown to be more significant for the thin tissue. We also examine the effects of the stiffness of the subchondral bone on the response of the soft tissue and demonstrate that the subchondral bone substrate can be modeled as a rigid, impermeable boundary. The effects of a curved tissue-subchondral bone interface, and the early time response are also studied. For physiologically reasonable levels of curvature, we will show that the curved tissue-subchrondral bone interface has negligible influence on the tissue response away from the interface. In addition, the short-time stress-relaxation responses of the tissue (e.g., at times less than 1s) demonstrate the essential role of the fluid phase in supporting the load applied to the tissue, and by extrapolation to shorter times characteristics of normal joint motion, suggest the essential role of a biphasic model in representing soft tissue behavior in joint response.
Skip Nav Destination
Article navigation
Research Papers
A Finite Element Analysis of the Indentation Stress-Relaxation Response of Linear Biphasic Articular Cartilage
Robert L. Spilker,
Robert L. Spilker
Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, NY 12180
Search for other works by this author on:
Jun-Kyo Suh,
Jun-Kyo Suh
Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, NY 12180
Search for other works by this author on:
Van C. Mow
Van C. Mow
Departments of Orthopaedic Surgery and Mechanical Engineering, Columbia University, New York, NY 10032
Search for other works by this author on:
Robert L. Spilker
Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, NY 12180
Jun-Kyo Suh
Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, NY 12180
Van C. Mow
Departments of Orthopaedic Surgery and Mechanical Engineering, Columbia University, New York, NY 10032
J Biomech Eng. May 1992, 114(2): 191-201 (11 pages)
Published Online: May 1, 1992
Article history
Received:
February 1, 1991
Revised:
October 10, 1991
Online:
March 17, 2008
Citation
Spilker, R. L., Suh, J., and Mow, V. C. (May 1, 1992). "A Finite Element Analysis of the Indentation Stress-Relaxation Response of Linear Biphasic Articular Cartilage." ASME. J Biomech Eng. May 1992; 114(2): 191–201. https://doi.org/10.1115/1.2891371
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Biphasic Finite Element Modeling of Hydrated Soft Tissue Contact Using an Augmented Lagrangian Method
J Biomech Eng (November,2011)
Inhomogeneous Cartilage Properties Enhance Superficial Interstitial Fluid Support and Frictional Properties, But Do Not Provide a Homogeneous State of Stress
J Biomech Eng (October,2003)
A Large Strain Material Model for Soft Tissues With Functionally Graded Properties
J Biomech Eng (July,2010)
A Lagrange Multiplier Mixed Finite Element Formulation for Three-Dimensional Contact of Biphasic Tissues
J Biomech Eng (June,2007)
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Effects of Ultrasound Stimulation on Chondrocytes in Three-Dimensional Culture in Relation to the Production of Regenerative Cartilage Tissue
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Conditions That Can Make an A/C System Unacceptable
Heat Exchanger Engineering Techniques