A model for the static pressure-volume behavior of the lung parenchyma based on a pseudo-elastic strain energy function was tested. Values of the model parameters and their variances were estimated by an optimal least-squares fit of the model-predicted pressures to the corresponding data from excised, saline-filled dog lungs. Although the model fit data from twelve lungs very well, the coefficients of variation for parameter values differed greatly. To analyze the sensitivity of the model output to its parameters, we examined an approximate Hessian, H, of the least-squares objective function. Based on the determinant and condition number of H, we were able to set formal criteria for choosing the most reliable estimates of parameter values and their variances. This in turn allowed us to specify a normal range of parameter values for these dog lungs. Thus the model not only describes static pressure-volume data, but also uses the data to estimate parameters from a fundamental constitutive equation. The optimal parameter estimation and sensitivity analysis developed here can be widely applied to other physiologic systems.
Skip Nav Destination
Article navigation
November 1985
Research Papers
Parameter Estimation and Sensitivity Analysis of a Nonlinearly Elastic Static Lung Model
J. R. Ligas,
J. R. Ligas
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106
Search for other works by this author on:
G. M. Saidel,
G. M. Saidel
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106; also, VA Medical Center, Cleveland, Ohio 44106
Search for other works by this author on:
F. P. Primiano, Jr.
F. P. Primiano, Jr.
Departments of Pediatrics and Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106
Search for other works by this author on:
J. R. Ligas
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106
G. M. Saidel
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106; also, VA Medical Center, Cleveland, Ohio 44106
F. P. Primiano, Jr.
Departments of Pediatrics and Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106
J Biomech Eng. Nov 1985, 107(4): 315-320 (6 pages)
Published Online: November 1, 1985
Article history
Received:
October 31, 1984
Revised:
June 28, 1985
Online:
June 15, 2009
Article
Article discussed|
View article
Connected Content
Citation
Ligas, J. R., Saidel, G. M., and Primiano, F. P., Jr. (November 1, 1985). "Parameter Estimation and Sensitivity Analysis of a Nonlinearly Elastic Static Lung Model." ASME. J Biomech Eng. November 1985; 107(4): 315–320. https://doi.org/10.1115/1.3138562
Download citation file:
Get Email Alerts
Cited By
A New Dissipation Function to Model the Rate-Dependent Mechanical Behavior of Semilunar Valve Leaflets
J Biomech Eng (July 2023)
Muscle Constitutive Model With a Tangent Modulus Approximation: Ansys Implementation and Verification
J Biomech Eng (July 2023)
Related Articles
Targeted Versus Continuous Delivery of Volatile Anesthetics During Cholinergic Bronchoconstriction
ASME J of Medical Diagnostics (August,2018)
Experimentally Validated Microstructural 3D Constitutive Model of Coronary Arterial Media
J Biomech Eng (March,2011)
Microcirculation Impedance Analysis in Cat Lung
J Biomech Eng (February,2000)
Bayesian Parameter Estimation of Convective Heat Transfer Coefficients of a Roof-Mounted Radiant Barrier System
J. Sol. Energy Eng (May,2006)
Related Proceedings Papers
Related Chapters
Advances in Computational Modeling of Sound Propagation in the Lungs and Torso with Diagnostic Applications
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices