Abnormal patellar tracking is the main cause of patellofemoral disorders and revision surgeries after total knee replacements (TKA) [1]. The decision to resurface or keep the natural patella has been an ongoing debate when performing TKA since patella morphology and femoral implant design affects patello-femoral (PF) kinematics during gait [2]. A previous study investigated the effects of resurfacing versus unresurfacing the patellae inter-specimen [3]. Error introduced in subject to subject studies can be reduced by performing a cadaveric study where PF kinematics for different patellae geometries are implanted in the same specimen. The purpose of this study was to measure PF kinematics in vitro during three simulated gait cycles with natural, unresurfaced, an anatomical design, and medialized dome patellae to determine the effects of different patellae design and gait cycles on PF kinematics.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
The Effect of Geometry on Patellar Tracking After TKA During Simulated Gait
Lauren Ferris,
Lauren Ferris
University of Kansas, Lawrence, KS
Search for other works by this author on:
Sami Shalhoub,
Sami Shalhoub
University of Kansas, Lawrence, KS
Search for other works by this author on:
Lorin Maletsky
Lorin Maletsky
University of Kansas, Lawrence, KS
Search for other works by this author on:
Lauren Ferris
University of Kansas, Lawrence, KS
Sami Shalhoub
University of Kansas, Lawrence, KS
Lorin Maletsky
University of Kansas, Lawrence, KS
Paper No:
SBC2012-80438, pp. 1063-1064; 2 pages
Published Online:
July 19, 2013
Citation
Ferris, L, Shalhoub, S, & Maletsky, L. "The Effect of Geometry on Patellar Tracking After TKA During Simulated Gait." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 1063-1064. ASME. https://doi.org/10.1115/SBC2012-80438
Download citation file:
3
Views
0
Citations
Related Proceedings Papers
Related Articles
Total Knee Replacement Polyethylene Stresses During Loading in a Knee Simulator
J. Tribol (October,2001)
Utility of Periurethral Electric Stimulation to Reduce Voiding Frequency in Rats
J. Med. Devices (June,2009)
Evaluation of a Surrogate Contact Model in Force-Dependent Kinematic Simulations of Total Knee Replacement
J Biomech Eng (August,2017)
Related Chapters
Infinitesimal Mechanics of the PKMs
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
A Method for Matching Two-Dimensional Contours
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3