The purpose of this study is to assess the kinematical changes in the flexion of the finger joints after MCP arthroplasty. Angular joint position in relation to its corresponding excursion was used to quantify the kinematics of the finger. The assessment used real time data acquisition and fresh-frozen cadaver hands. Several important benchmarks were considered in analyzing the data. First of all, the initiation of the digit was considered. When a tendon is pulled, motion is normally observed in the DIP first, followed by the PIP, and finally the MCP. This order should be maintained after the arthroplasty. For our kinematics study, it is also important to note any significant increase or decrease in the time of the initiation. Other benchmarks we considered include the starting and ending angle of the joints. The start and ending angle is important when studying the overall range of motion of the digit. The overall range of motion affects basic hand function and is one measure of successful arthroplasty. Excursion was also considered as an overall measure of how well the prosthesis mimics the original joint. Large changes in excursion could indicate that the original center of rotation has not been maintained.
Skip Nav Destination
ASME 2003 International Mechanical Engineering Congress and Exposition
November 15–21, 2003
Washington, DC, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-3710-6
PROCEEDINGS PAPER
Analysis of Finger Joint Kinematics Before and After MCP Joint Arthroplasty
David McNeal,
David McNeal
University of Illinois at Chicago, Chicago, IL
Search for other works by this author on:
Bassem elHassan,
Bassem elHassan
University of Illinois at Chicago, Chicago, IL
Search for other works by this author on:
Farid Amirouche,
Farid Amirouche
University of Illinois at Chicago, Chicago, IL
Search for other works by this author on:
Mark Gonzalez
Mark Gonzalez
University of Illinois at Chicago, Chicago, IL
Search for other works by this author on:
David McNeal
University of Illinois at Chicago, Chicago, IL
Bassem elHassan
University of Illinois at Chicago, Chicago, IL
Farid Amirouche
University of Illinois at Chicago, Chicago, IL
Mark Gonzalez
University of Illinois at Chicago, Chicago, IL
Paper No:
IMECE2003-42990, pp. 173-174; 2 pages
Published Online:
May 12, 2008
Citation
McNeal, D, elHassan, B, Amirouche, F, & Gonzalez, M. "Analysis of Finger Joint Kinematics Before and After MCP Joint Arthroplasty." Proceedings of the ASME 2003 International Mechanical Engineering Congress and Exposition. Advances in Bioengineering. Washington, DC, USA. November 15–21, 2003. pp. 173-174. ASME. https://doi.org/10.1115/IMECE2003-42990
Download citation file:
3
Views
0
Citations
Related Proceedings Papers
Related Articles
Simulation and Animation of Musculoskeletal Joint System
J Biomech Eng (November,1993)
Joint Gap Kinematics in Posterior-Stabilized Total Knee Arthroplasty Measured by a New Tensor With the Navigation System
J Biomech Eng (December,2006)
Simultaneous In Vitro Measurement of Patellofemoral Kinematics and Forces
J Biomech Eng (June,2004)
Related Chapters
Some Recent Advances and Current Challenges in Joint-Replacement Tribology and UHMWPE Bearing Surfaces
Tribology of Mechanical Systems: A Guide to Present and Future Technologies
Accumulated Step Deviation Method for Automatic Fuzzy Set Generation
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Study on the Method of Multirate Data Processing System
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)