Proc. ASME. ICONE2020, Volume 2: Nuclear Policy; Nuclear Safety, Security, and Cyber Security; Operating Plant Experience; Probabilistic Risk Assessments; SMR and Advanced Reactors, V002T09A006, August 4–5, 2020
Paper No: ICONE2020-16525
... possible. 95% of all collected process data can be discarded after introduction of CPDR. With CPDR, plant operation and maintenance can be significantly optimized and utilities can profit by realizing e.g. power recovery and measurement uncertainty recapture (MUR). Because the focus on reconciled instead...
Proceedings Papers

Proc. ASME. ICONE17, Volume 3: Thermal Hydraulics; Current Advanced Reactors: Plant Design, Construction, Workforce and Public Acceptance, 381-387, July 12–16, 2009
Paper No: ICONE17-75399
... 23 02 2010 The reactor coolant system (RCS) pressure transients under ATWS for Maanshan PWR with MUR conditions were analyzed in this study. The main concern was to observe whether the peak RCS pressure still maintained within 3200 psig limit (defined by ASME Code Level C service limit...