High speed visualization of boiling pentane in a circular steel tube (Di = 1.2 mm, Do = 2 mm) has been performed at the Neutrograph instrument at the Institut Laue-Langevin in Grenoble, France. The heat and mass flux were both very low and appropriate for cooling of PEM fuel cells. The spatial resolution of the images is approximately 0.15 mm and the maximum frequency is 154 Hz. In the images, the liquid-vapor differentiation is clearly visible. Time resolved measurements of the outer pipe wall temperature, synchronized with the images, show that at low mass flow rates, the pipe wall is high above the saturation temperature and the pipe filled with vapor and liquid slugs. At higher flow rates, the wall is superheated when filled with liquid and at saturation temperature during boiling when exposed to a liquid-vapor mixture. An irregular switching between these two states was observed. The superheated wall is shown to be consistent with superheated liquid in the pipe prior to boiling. Unfortunately the strong γ-radiation produced by the neutrons has a substantial effect on the onset of boiling, which is why comparisons with non-irradiated systems might be difficult.
Skip Nav Destination
ASME 2004 2nd International Conference on Microchannels and Minichannels
June 17–19, 2004
Rochester, New York, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4164-2
PROCEEDINGS PAPER
Visualization of Low Heat and Mass Flux Boiling in a Small Metal Pipe Using Neutron Radiography
K. M. Oseen-Senda,
K. M. Oseen-Senda
CEA/GRETh Grenoble, Grenoble, France
Search for other works by this author on:
F. Lundell,
F. Lundell
CEA/GRETh Grenoble, Grenoble, France
Search for other works by this author on:
A. Hillenbach,
A. Hillenbach
Institut Laue-Langevin, Grenoble, France
Search for other works by this author on:
J. Pauchet
J. Pauchet
CEA/GRETh Grenoble, Grenoble, France
Search for other works by this author on:
K. M. Oseen-Senda
CEA/GRETh Grenoble, Grenoble, France
F. Lundell
CEA/GRETh Grenoble, Grenoble, France
A. Hillenbach
Institut Laue-Langevin, Grenoble, France
J. Pauchet
CEA/GRETh Grenoble, Grenoble, France
Paper No:
ICMM2004-2374, pp. 499-505; 7 pages
Published Online:
December 2, 2008
Citation
Oseen-Senda, KM, Lundell, F, Hillenbach, A, & Pauchet, J. "Visualization of Low Heat and Mass Flux Boiling in a Small Metal Pipe Using Neutron Radiography." Proceedings of the ASME 2004 2nd International Conference on Microchannels and Minichannels. ASME 2nd International Conference on Microchannels and Minichannels. Rochester, New York, USA. June 17–19, 2004. pp. 499-505. ASME. https://doi.org/10.1115/ICMM2004-2374
Download citation file:
3
Views
0
Citations
Related Proceedings Papers
Related Articles
Assessment of CHF Enhancement Mechanisms in a Curved, Rectangular Channel Subjected to Concave Heating
J. Heat Transfer (May,1999)
Heat Transport Capability and Fluid Flow Neutron Radiography of Three-Dimensional Oscillating Heat Pipes
J. Heat Transfer (June,2010)
Elucidating Liquid Water Distribution and Removal in an Operating Proton Exchange Membrane Fuel Cell via Neutron Radiography
J. Fuel Cell Sci. Technol (February,2010)
Related Chapters
Measurement of Hydrogen Distributions in Metals by Neutron Radiography and Tomography
International Hydrogen Conference (IHC 2016): Materials Performance in Hydrogen Environments
Liquid Cooled Systems
Thermal Management of Telecommunications Equipment
Even a Watched Pot Boils Eventually
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong