0
RESEARCH PAPERS

The Design and Testing of a Highly Insulating Glazing System for Use With Conventional Window Systems

[+] Author and Article Information
Dariush Arasteh, Stephen Selkowitz, John R. Wolfe

Applied Science Division, Lawrence Berkeley Laboratory, University of California, Berkeley, Calif. 94720

J. Sol. Energy Eng 111(1), 44-53 (Feb 01, 1989) (10 pages) doi:10.1115/1.3268286 History: Received July 01, 1988; Revised November 01, 1988; Online November 11, 2009

Abstract

In most areas of the United States, windows are by far the poorest insulating material used in buildings. As a result, approximately 3 percent of the nation’s energy use is used to offset heat lost through windows. Under cold conditions, conventional double glazings create uncomfortable spaces and collect condensation. However, with the recent introduction of low-emissivity (low-E) coatings and low/conductivity gas filling to respectively reduce radiative and conductive/convective heat transfer between glazing layers, some manufacturers are beginning to offer windows with R-values (resistance to heat transfer) of 4 hr-ft2 -F/Btu (0.70 m2 -C/W). This papers presents designs for and analysis and test results of an insulated glass unit with a center-of-glass R-value of 8-10; approximately twice as good as gas-filled low-E units, and four times that of conventional double glazing. This high-R design starts with a conventional insulated-glass unit and adds two low-emissivity coatings, a thin glass middle glazing layer, and a Krypton or Krypton/Argon gas fill. The unit’s overall width is 1 in. (25 mm) or less, consistent with most manufacturers’ frame and sash design requirements. Using state-of-the-art low-emissivity coatings does not significantly degrade the solar heat gain potential or visible transmittance of the window. Work to date has substantiated this concept of a high-R window although specific components require further research and engineering development. Demonstration projects, in conjunction with utilities and several major window manufacturers, are planned. This high-R window design is the subject of a DOE patent application.

Copyright © 1989 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In